75 Ohm Coaxial Cable

RG11U

Abbreviation Legend

Coaxial Handbook

BNC Jacks

BNC Plugsw

ECS
Catalogue
Number

RG#

Conductor

Insul.

Jacket & O.D.
(inches)

Shields & Type

Nom.
IMP.
(ohms)

Nom. Vel. of Prop.

Nom. CAP pF/ft.

Approval

Rating

Total
Weight
(lbs/km)

Nom. Attenuation 

Size

Stranding

Type

MHz

db/100'

RG11-1 11U 14 Solid GPE PE

BFL&60%

75 82% 16.2 197 55 0.96
Black Burial CCS .395 AB 83 1.18

Commscope #5914

211 1.90
300 2.25
400 2.60
500 2.90
600 3.18

ECS
Catalogue
Number

RG#

Conductor

Insul.

Jacket & O.D.
(inches)

Shields & Type

Nom.
IMP.
(ohms)

Nom. Vel. of Prop.

Nom. CAP pF/ft.

Approval

Rating

Total
Weight
(lbs/km)

Nom. Attenuation 

Size

Stranding

Type

MHz

db/100'

RG11-2 11AU 18 7 X 26 PE

PVC 95% 75 66% 20.5   197 1 0.20

Black

TC

.405

BCB

 

10

0.70

50

1.50

 

100 2.10
200 3.20

500

5.00

1000

8.00

ECS
Catalogue
Number

RG#

Conductor

Insul.

Jacket & O.D.
(inches)

Shields & Type

Nom.
IMP.
(ohms)

Nom. Vel. of Prop.

Nom. CAP pF/ft.

Approval

Rating

Total
Weight
(lbs/km)

Nom. Attenuation 

Size

Stranding

Type

MHz

db/100'

RG11-3 11U 14 Solid FPE PVC FL&60% 75 82% 16.2 CSA 219 10 0.81
Black

 

CCS .405 AB CMG/FT4 50 1.46

100 2.05
200 2.83
400 4.05
700 5.60
900 6.23
1000 6.59

ECS
Catalogue
Number

RG#

Conductor

Insul.

Jacket & O.D.
(inches)

Shields & Type

Nom.
IMP.
(ohms)

Nom. Vel. of Prop.

Nom. CAP pF/ft.

Approval

Rating

Total
Weight
(lbs/km)

Nom. Attenuation 

Size

Stranding

Type

MHz

db/100'

RG11-4 11U 14 Solid FPE PVC 95% 75 78% 17.3 CSA 219 50 1.00
Black

 

BC .405 BCB CMH/FT1 100 1.50

200 2.20
500 3.70
900 5.20

ECS
Catalogue
Number

RG#

Conductor

Insul.

Jacket & O.D.
(inches)

Shields & Type

Nom.
IMP.
(ohms)

Nom. Vel. of Prop.

Nom. CAP pF/ft.

Approval

Rating

Total
Weight
(lbs/km)

Nom. Attenuation 

Size

Stranding

Type

MHz

db/100'

RG11-5 11U 14 Solid FPE PVC FL&60% 75 82% 16.2 CSA 219 1 0.18
Black

MATV

BC .405 TCB CMH/FT1 10 0.35

Commscope #3109

 

50 0.81
100 1.14
200 1.63
400 2.35
700 3.20
900 3.63
1000 3.83

ECS
Catalogue
Number

RG#

Conductor

Insul.

Jacket & O.D.
(inches)

Shields & Type

Nom.
IMP.
(ohms)

Nom. Vel. of Prop.

Nom. CAP pF/ft.

Approval

Rating

Total
Weight
(lbs/km)

Nom. Attenuation 

Size

Stranding

Type

MHz

db/100'

RG11-6 11U 14 Solid FPE FRPVC

FL&60%

FL&40%

75 84% 16.0 CSA 219 1 0.22
Black

Quad

Shield

CCS .405 AB CMH/FT1 10 0.49

Commscope #5940

 

50 0.98
100 1.29
200 1.78
400 2.68
700 3.67
900 4.25
1000 4.52
1200 4.91
1450 5.39
1800 6.01
2200 6.64

ECS
Catalogue
Number

RG#

Conductor

Insul.

Jacket & O.D.
(inches)

Shields & Type

Nom.
IMP.
(ohms)

Nom. Vel. of Prop.

Nom. CAP pF/ft.

Approval

Rating

Total
Weight
(lbs/km)

Nom. Attenuation 

Size

Stranding

Type

MHz

db/100'

RG11-7 11U 14 Solid GPE PVC

BFL&60%

75 85% 16.0   288 5 0.38
Black   CCS .395 AB   55 0.96

 

 

 

With .072" Steel Messenger

Commscope #5910

 

83 1.18
187 1.75
211 1.85
250 2.05
300 2.25
350 2.42
400 2.60
450 2.75
500 2.90
600 3.18
750 3.65
865 3.98
1000 4.35